marches et garde-corps. STANDARD. ISO. Second edition. Reference number. ISO (E). Provläsningsexemplar / Preview. 27 Jul Kee Safety has amended its Kee Gate range to ensure compliance with the new requirements of BS EN ISO The revised BS EN. This second edition cancels and replaces the first edition (ISO ) which has been technically revised. It also incorporates the Amendment ISO.

Author: Momi Yogore
Country: Hungary
Language: English (Spanish)
Genre: Environment
Published (Last): 13 December 2010
Pages: 240
PDF File Size: 1.81 Mb
ePub File Size: 11.84 Mb
ISBN: 564-8-20532-576-6
Downloads: 14571
Price: Free* [*Free Regsitration Required]
Uploader: Galkree

The gates are also spring loaded, ensuring that they automatically close behind the user to protect against human error. However, the scope of the standard specifically excludes powered means of access lifts, escalators or other bs en iso 14122-3 designed to move persons between levels. We use cookies to make our website easier to use and to better understand your needs. More about your enquiry.

Nevertheless, it would be prudent to verify the safety requirements either by calculation or testing. Leave a Reply Cancel reply You must be logged in to post a comment.

Safety gate range enhanced to BS EN ISO 14122-3:2016

A permanent means of access is fixed to the machine or an adjacent structure in such a way that it cannot be removed without the use of tools. Overview Product Details What is this standard about?

Document Status Indicators The Green document status indicator indicates that the document is: For example, rather than require an access point so that lubrication points bs en iso 14122-3 be reached, lubrication points should be made accessible from ground level or a lubrication bs en iso 14122-3 and pump could be installed.

Code of practice for the design of industrial type stairs, permanent ladders and walkways Withdrawn. Clause 7Specific requirements applicable to guard-railsstates that guard-rails shall be installed when the height of the possible fall exceeds mm, if the gap between the platform bs en iso 14122-3 machine structure exceeds mm or if the protection provided by the structure is not equivalent to a guard-rail.

This site uses cookies No problem More info. However, it is almost inevitable that Part 3 will also be required, because this covers the guard-rails that are usually necessary with platforms and walkways. Interestingly, a pragmatic approach is adopted, with several exceptions allowed under particular circumstances. Kee Safety manufactures the Kee Gate from galvanised steel, with the option of powder coating it in safety yellow to individual specification. It states that a guardrail should be fitted when the height of a fall could exceed mm; the specified bs en iso 14122-3 needs to meet a number of dimensional requirements and a self-closing gate should also be used.

The clause goes on to provide details of how to test guard-rails and the steps of a stair. A final point to note is that ISO Part 5 is in preparation, which will deal with permanent means of access on mobile machinery.

Machine manufacturers small, medium and large enterprises Health and safety bodies regulators, accident prevention organizations, market surveillance, etc. Procter Machine Guarding offers free Machine Guarding Compliance Surveys of standalone machinery and assemblies of machines, old or new, and can also assess permanent means isp access.

Safety gate range enhanced to BS EN ISO

Stairways, stepladders and guard-rails Withdrawn. If guard-rails are being installed alongside sn or walkways, Part 3 will have to be used in conjunction with Part 2 as well. Find Similar Items This product falls into the following categories.

Take the smart route to manage medical device compliance. Conveyor Guarding Explaining the hazards associated with conveyors, regulations and standards, and how to safeguard conveyors without adversely affecting productivity. Furthermore, a permanent means of access can prove to be very cost-effective compared with the cost of erecting scaffolding on multiple occasions.

Annex B informative illustrates the main dimensions of a fixed ladder equipped with a safety cage. When most people refer to stepladders they probably mean a short ladder with folding legs that enable it to be free-standing.

Kee Safety has ido added a mid rail, minimising em gap between the top of the gate and the bottom rail. Part 1 contains useful definitions, such bs en iso 14122-3 those for fixed ladder, stepladder, stair and ramp essentially the differences relate to the angle of pitch, and ladders have rungs whereas stepladders and stairs have steps. There is no option in the Annex for verifying the safety requirements by calculation.

Clause 5 lists the general requirements for design bs en iso 14122-3 construction of means of access. You may experience issues viewing this site in Internet Explorer 9, 10 or Note that subclause 6. For the purposes of BS EN ISOpermanent means of access are working platforms, walkways, stairs, stepladders, guard rails and fixed ladders. The modified gate is mm high and 1m wide; its mid rail is positioned mm from the top rail, whilst its bottom rail is raised mm from the floor.

If the designer chooses bs en iso 14122-3 verify the safety requirements bs en iso 14122-3 calculation, the information relating to the test methods must be taken into account so that the two verification methods are comparable. Clause 5Specific requirements of ladder systemsprovides extensive information relating to ladder design, including the profiles and dimensions of rungs round rungs bs en iso 14122-3 not permitted.

Some eh bs en iso 14122-3 provided for designers, as shown by this example from subclause 5. The four parts are all B-Type standards, meaning they deal with specific aspects of machinery safety and can be applied to a wide range of categories of machinery.

BS EN ISO 14122-3:2016

Annex C lists the significant technical changes between ISO Another point to note from the definitions is that handrails must be rigid, which excludes the use of ropes, chains or cables. I accept the privacy policy.

You must be logged in to post a comment. However, the same subclause states that the minimum height of the guard-rail shall be mm, so it appears that the former may be a typographical error and the height of the handrail should be greater than or equal to mm. Click bs en iso 14122-3 to find out how to access this document.

Clause 4 of Part 1 lists the most significant hazards bs en iso 14122-3 consider when determining the type and location of the means of access. Clause 6Specific requirements applicable to step laddersprovides similar details to those in Clause 5. The previous editions cease 14122–3 provide a presumption of conformity to the Machinery Directive bw 31 December It will be used by: References are made to other subclauses that help in determining which type of access should be selected, but the point to note is that there must be good reasons for using any means of access other than those listed higher up the hierarchy.

One issue that is not addressed particularly well in the standard is the question of under what 141122-3 a permanent means of access is required, though an ISO risk assessment 1122-3 help.

Stairs, stepladders and guard-rails ISO Clause 8Verification of safety requirementseh a choice of testing or calculation. In other words, when designing and specifying means of access, consideration should be given to preventing unauthorised access. For testing stepladders, the reader is referred to Bs en iso 14122-3Bs en iso 14122-3.